> Manual
> Comparison Chart
|
|
DM6650T True RMS 10 Function Digital Multimeter
|
- Precise True RMS circuitry for accurate readings of non-linear waveforms
- Integrated non-contact voltage detection
- Relative Delta displays change in readings
- Min/Max function to hold either minimum reading or maximum reading on the display
- Data hold feature captures reading on the display
- Large backlit LCD display with bar graph indication
- Impact resistant housing with protective rubber boot
- Operates from one 9 volt battery
|
| DM6650T |
|
Range |
|
Accuracy |
|
| DC Voltage |
|
40mV, 400mV, 4V, 40V, 400V, 1000V |
|
40mV (1.2%+5dgt) 400mV
(0.8%+3dgt) 4V 40V 400V (0.8%+1dgt) 1000V (1.0%+3dgt) |
| AC Voltage |
|
40mV, 400mV, 4V, 40V, 400V, 750V |
|
40mV (1.2%+5dgt) 4V 40V 400V (1.0%+5dgt) 400mV 750V (1.2%+5dgt) |
| Non Contact AC Voltage |
|
80-1000V AC |
|
- |
| DC Amps |
|
400uA,4000uA,40mA 400mA, 4A, 10A |
|
400µA 4000µA (1.0%+2dgt)
40mA 400mA (1.2%+3dgt) 4A 10A (1.5%+5dgt) |
| AC Amps |
|
400uA, 4000uA, 40mA, 400mA, 4A, 10A |
|
400µA 4000µA (1.2%+2dgt) 40mA 400mA (1.5%+3dgt) 4A 10A Ω(2.0%+3dgt) |
| Resistance |
|
400Ω, 4K, 40K, 400K, 4M, 40MΩ |
|
400 4M (1.2%+2dgt)4K 40K 400K (1.0%+2dgt) 40M (1.5%+2dgt) |
| Capacity |
|
40nF, 400nF, 4uF, 40uF 400uF, 4000uF |
|
40µF (3.0%+10dgt) 400µF
4µF 40µF (3.0%+5dgt) 400µF
40000µF (4.0%+5dgt)
|
| Frequency |
|
100Hz-10MHz |
|
0.1%+3dgt |
| Diode Test |
|
 |
|
- |
| Continuity |
|
 |
|
- |
| CAT Rating |
|
IV 600V, III 1000V |
|
- |
|
|